Casablanca, Morocco

The Faubourg d’Anfa

The Faubourg d’Anfa, one of the first apartment complexes developed by Bouygues Immobilier and built by MARO. This project includes 390 apartments and shops on the ground floor. This development has qualified for HQE 3 certification, thanks in particular to its renewable energy production capacity. Being built next to it is BO52, another HQE certified eco-neighborhood, with 150 apartments. Linkcity Maroc, the property development subsidiary of Bouygues Construction, is carrying out this project.

Project info

Construction phase
New construction
Building type
Multi Family House (MFH)
Detailed building type
Multi Family House / Apartment block - Large (> 1000m²) - detached
Net floor area
43200 m2
Land plot size
350000 m2
Stories
8 stories
Construction type
Mixed construction
Original construction year of the building
2018
Project contact
The Bouygues Group in Morocco
Contact email address
presse@bouygues.com

Project team

Developer(s)/owner(s)
The Bouygues Group in Morocco
Architect(s)
Omar Alaoui

Building Rating and Certifications systems

Rating and certifications systems
Other
Other certification
HQE

Building Envelope

External walls

Description of construction
Concrete plaster, concrete block, rockwool, concrete block, concrete plaster.
U-Value
0.49 W/(m²*K)

Roof

Roof type
Flat roof
Description of construction
Marble, floating screed, resilient underlay, concrete slab
U-Value
0.58 W/(m²*K)

Openings and windows

Glazing type
Double glazed
Frame material / description
Glass, air blade, glass
Overall u-value window
3 W/(m²*K)

Basement floor

Description of construction
Marble, floating screed, resilient underlay, concrete slab.
U-Value
0.18 W/(m²*K)

Technical Building Systems

Ventilation system

Type of ventilation
VMC/MV System with air inlets / compensated air handling unit

Space cooling system

Primary space cooling system
Centralised multi-split system│Consisting of one outdoor unit (e.g. located on the rooftop) supplying several indoor units
Efficiency
3.5
Description
VRV Syst. (Variable refrigerant Volume), EER (Energy Efficiency Ratio) >=3.5
Manufacturer(s) / products
HITACHI

Space heating system

Description
Fan Coil Unit / COP (Coefficient Of Performance)>=4.1

Water heater system

Primary water heater system
Solar Thermal collector on the roof
Description
Individual electric boiler & Solar thermal
Manufacturer(s) / products
Ariston et Chaffoteau

Lighting system

Primary lighting system
LED (Light emitting diode lamps)
Efficiency
100
Description
Low-power exterior lighting and LED, E=100
Manufacturer(s) / products
PUK

Shading devices

Type of shading system installed
Manual systems (e.g. roller shutters, folding shutters, external blinds)

Photovoltaics

Manufacturer(s) / products
Ariston et Chaffoteau

Final Energy Demand

Total specific final energy demand
39,00 kWh/(m²*a)

Financial Aspects

Project construction cost
43550000 EUR
Estimated costs of energy efficiency and renewable energy measures
3484000 EUR